I-Adjustable Inductance AC Resonance Test System

 Apr 08, 2024

 Shiya umyalezo

 

XZB(L)-65000kVA/100kVAdjustable Inductance AC Resonance Test System

 

 

Uvavanyo lwesicelo

Amandla ombane e-Ac amelana novavanyo lwejenereyitha, Awona mandla ombane aphezulu ovavanyo aluyi kuba ngaphezu kwe-100kV,{1}}inqanaba elinye lamandla alikho ngaphezulu kwe-2uF.

Iiparamitha eziphambili zeTekhnoloji

Umthamo olinganisiweyo: 6500kVA;

Umbane olinganisiweyo: 100kV;

Ilinganiswe ngoku:65A;

Ukusebenza rhoqo: 50Hz;

Isantya sokugqwesa i-voltage ephumayo: Ngaphantsi okanye ilingana ne-0.5%;

Iiyure zokusebenza eziqhubekayo zivumelekile:uphantsi ko{0}}kumthwalo 5min

Emva kokulinganisa ngaphantsi{0}kumthwalo 5min ubaleka, iqondo lobushushu liyenyuka Ngaphantsi okanye lilingana ne65K

Umgangatho womgangatho: Q Inkulu kuno okanye ilingana no-10;

Ukuchaneka kovavanyo: ixabiso elisebenzayo 1.5;

Ukunikezelwa kwamandla okufakwayo: enye i-380Vvoltage, i-frequency 50Hz;

Inokhuseleko lwe-overcurrent, overpressure, kunye ne-flashover yokuvavanya iisampuli;

iqondo lobushushu bemeko-bume:-150C–{1}}C,ukufuma okunxulumeneyo: Ngaphantsi okanye ilingana ne-90%RH,ubude obungaphantsi okanye obulingana ne-1000m;

Umgangatho

I-GB10229-88 《i-reactor express

I-GB1094 《isiguquli samandla sivakalisa

GB50150-2016 《umgangatho wokunikezelwa kwezixhobo zombane kunye novavanyo lwekhomishini

DL/T 596-2021 《umgaqo wovavanyo lothintelo lwezixhobo zombane ezibonisayo

I-GB2900 《isigama se-electrotechnical express

I-GB/T16927.1 ~ 2-2011 《Ubuchule bokuvavanya amandla ombane aphezulu

Vavanya unikezelo lwamandla kunye ne-L, i-Cx yokulungelelanisa itshathi

Uluhlu lwamandla ovavanyo lwezinto

Uluhlu oluhlengahlengiswayo lwereactor

 

0.37~2uF

 

5.1H~27.4H

Phawula:Cx bubuchule bento yovavanyo

Uvavanyo lwamandla ombane we-AC luxhathise uvavanyo lombane: adopt series resonance test

usete ukwenza uvavanyo lwe-hipot yejeneretha ye-AC;

Indlela yoqhagamshelwano lweReactor

Umthamo wereactor(kVA)

Uvavanyo lombane (kV)

Uvavanyo lwangoku (A)

Uluhlu lwexabiso lokukwazi (uF)

Uluhlu lwexabiso le-inductance (H)

Irector ehlengahlengiswayo*1 iseti

3500kVA

100kV

35A

0.37-1.1

9.2-27.4H

1*I-reactor ehlengahlengiswayo+1*i-reactor ezinzileyo

3500kVA+1500kVA

100kV

50A

0.82-1.55

6.5-12.4H

1*ireactor ehlengahlengiswayo +2* ireactor esisigxina

3500kVA+1500kVA+1500kVA

100kV

65A

1.2-2

5.1-8.4H

Inkqubo kunye neeparamitha

i-transformer enomdla JLB-650kVA/10kV/0.4kV 1iseti

Umthamo olinganisiweyo: 650kVA;

Igalelo lombane:400V,enye;

Imveliso: 10kV

isakhiwo: oyile uhlobo

ubunzima: malunga ne-1.5T

emva kokulinganisa okusebenzayo1min, ikhoyili ifudumeza umoya: Ngaphantsi okanye ilingana no-65K;

Ciyunithi yokulawulaI-CHXB(L){0}}650kVA/380V 1iseti

Umthamo olinganisiweyo: 650kVA;

Igalelo: 380V;

imveliso: 0 ~ 420V;

Iimpawu zokhuseleko:Indawo yeZero, i-overcurrent, i-overpressure, kunye nokhuseleko lwe-flashover;

Ubunzima:malunga ne-1.2T

HV ehlengahlengiswayo DK(L)-3500kVA/100kV 1iseti

Umthamo olinganisiweyo: 3500kVA;

Umbane olinganisiweyo: 100kV;

Ilinganiswe ngoku:35A;

Ubunakho obunokulungiswa:9.2-27.4H;

Umgangatho womgangatho: Q Inkulu kuno okanye ilingana no-10;

Ulwakhiwo:udidi lweoyile;

Qty:1 iseti;

ubunzima:malunga ne2T

I-reactor esisigxinaDK-1500kVA/100kV2 SET

Umthamo olinganisiweyo: 1500KVA;

Umbane olinganisiweyo: 100kV;

Ilinganiswe ngoku:15A;

Ixabiso le-inductance: 22.5H;

Umgangatho womgangatho: Q Inkulu kuno okanye ilingana no-10;

isakhiwo: uhlobo lweoyile;

G): malunga ne-0.8T

Umahluli weHVFRC{0}}100kV 1 snjl

Umbane olinganisiweyo: 100kV;

Ukuchaneka komlinganiselo: 1.5 AC ixabiso elisebenzayo;

ilahleko ye-dielectric:tgσ Ngaphantsi okanye ilingana ne-0.5%;

Umlinganiselo wokwahlula amandla ombane:1500:1,

Impazamo yomlinganiselo wokwahlula amandla ombane: Ngaphantsi okanye ilingana ne-1.0%;

ubunzima: 15kg;

imbuyekezo capacitorBC-100kV/0.37uF1SET

Umbane olinganisiweyo: 100kV;

ilahleko ye-dielectric:tgσ Ngaphantsi okanye ilingana ne-0.5%;

Umthamo olinganiselweyo: 0.37uF

D): malunga ne-80kg;

Uluhlu lokupakisha

Hayi

Igama lesixhobo

Imodeli kunye ngqo

iyunithi

Qty

phawula

1

I-transformer evuyisayo

I-JLB-650kVA/10kV/0.4kV

iseti

1

 

2

Iyunithi yokulawula

I-CHXB (L) -650kVA/380V

iseti

1

 

3

I-reactor ehlengahlengiswayo

I-DK(L)-3500kVA/100kV

iseti

1

 

4

I-reactor esisigxina

DK-1500kVA/100kV

iseti

2

 

5

HV umahluli

FRC-100kV/1000pF

iseti

1

 

6

Ukuhlawula i-capacitor

BC-100kV/0.37uF

iseti

1

 

7

Iintambo zoqhagamshelo

 

iseti

1

 

 

Iimpawu zenkqubo kunye nemisebenzi

I-Counterattack overvoltage kunye nokudluliselwa kokukhuselwa kwe-overvoltage: le nkqubo

yamkele indlela elungileyo yocingo kunye nomsebenzi wokukhusela kwaye inokufunxa amandla ngokuthe ngcembe

ukuphepha umonakalo wokulwa nokutshatyalaliswa kwe-overvoltage kunye nokudlulisa i-overvoltage. Emva kweminyaka yokuziqhelanisa ebaleni, xa iSampulu ikwiflashover okanye ucazululo, inokukhusela iseti yovavanyo kunye{1}}nendawo yabavavanyi ukusuka{2}}ngaphezulu kombane. Okwangoku, iphinda igweme ukuchitha umonakalo emva kokuba indawo yephutha i-flashover kwaye iphukile.

Ubungakanani obuncinci, ukhaphukhaphu, ufakelo olulula kunye nokuphathwa, iingcingo ezilula, zilungele ukusebenza kwabasebenzi bendawo-.

Imisebenzi ephambili yile ingezantsi:

(1)I-reactor core gap yokufunda ngokuthe ngqo umsebenzi

Isixhobo sixhotyiswe ngomngxuma wokujonga i-gap kwi-reactor, enokufunda ngokuthe ngqo i-gap ye-core yentsimbi ukukhokela ukusebenza, kwaye ixhotyiswe nge-gap limit limit switch kunye nesalathisi.

(2) Ukumelana nexesha lombane kumsebenzi ozenzekelayo we-buck:

Ukumelana nexesha lombane usebenzisa isibali-xesha sedijithali. Kwaye xa ixesha lokumelana ne-voltage lifikelelwe, inkqubo iya kunciphisa ngokuzenzekelayo i-voltage

Ukuvala indawo ye-zero, umsebenzi wokunyusa amandla ombane wero:

Ngomsebenzi womda we-zero, ukuba umlawuli akakho kwindawo ye-zero, iqhosha lokukhupha i-voltage ephezulu ayikwazi ukuvalwa ukuqinisekisa ukuba inkqubo iphakanyisiwe ukusuka kwi-zero.

Umsebenzi wokhuseleko wangoku:

Inkqubo ixhotyiswe nge-electromagnetic overcurrent relay, ene-anti-ikhono eliphazamisayo elinamandla kunye nesenzo esikhawulezayo ukunqanda imveliso yovavanyo ukuba yonakaliswe ngoku.

Ukugqithisa kunye nomsebenzi wokukhusela umxholo we-flashover:

Isixhobo sixhotyiswe nge-electronic overvoltage kunye nepleyiti yokukhusela i-flashover ukukhusela imveliso yokuvavanya ukuba ingalinyazwa ngokugqithisileyo kunye ne-flashover, kwaye isenzo sikhawuleza.

ixesha lokwenyani-lomsebenzi wokubeka iliso kwidatha yovavanyo ngalunye:

Umbane {{0}okhoyo wecala lombane ophezulu kunye nombane okhoyo kwicala lamandla ombane ophantsi unokujongwa, kwaye imeko yovavanyo inokuqondwa ngokucace ngakumbi.

Thumela u kuphanda