Ukuvavanya i-SF6 i-breaker circuit circuit ibalulekile ekuqinisekiseni ukusebenza kwayo ngokufanelekileyo kunye nokhuseleko. Kukho iimvavanyo ezahlukeneyo ezinokuthi zenziwe ukuqinisekisa ukuba i-breaker circuit ikwimeko efanelekileyo. Kweli nqaku, siza kuxubusha ezinye iimvavanyo ezibalulekileyo ekufuneka zenziwe kwi-SF6 gas circuit breaker.
1. Uvavanyo lwe-Insulation Resistance
Uvavanyo lokumelana ne-insulation lwenziwa ukujonga ukuxhatshazwa kwe-insulation ye-breaker circuit. Ukwenza olu vavanyo, i-breaker circuit ihlukaniswe kumthombo wamandla, kwaye ke i-voltage ye-500V DC isetyenziswe kwiipali. Ukuxhatshazwa kwe-insulation kungabalwa ngokulinganisa i-current ejikelezayo kwi-insulation kwaye emva koko usebenzisa umthetho we-Ohm ukubala ukuchasana.
2. Qhagamshelana noVavanyo lokuChasa
Uvavanyo lokumelana noqhagamshelwano lwenziwa ukujonga ukuchasana koqhagamshelwano lwe-breaker circuit. Olu vavanyo lwenziwa ukuqinisekisa ukuba abafowunelwa bacocekile kwaye benza uqhagamshelwano olufanelekileyo. Ukwenza olu vavanyo, unikezelo lwe-DC oluphantsi{2}}lusetyenziswa kubo bonke abafowunelwa abavaliweyo be-breaker circuit. Ukuhla kwe-voltage kwi-contacts kulinganiswa, kwaye ukuchasana koqhagamshelwano kunokubalwa ngokusebenzisa umthetho we-Ohm.
3. Uvavanyo lwexesha
Uvavanyo lwexesha lwenziwa ukujonga isantya sokusebenza kwe-breaker circuit. Olu vavanyo lwenziwa ukuze kuqinisekiswe ukuba i-breaker circuit isebenza ngaphakathi kwemida yexesha elichaziweyo. Ukwenza olu vavanyo, i-analyzer ye-circuit breaker ixhunyiwe kwi-breaker circuit, kwaye ixesha lokusebenza kwe-breaker lilinganiswa. Iziphumo ke zithelekiswa neenkcukacha zomenzi wokuqinisekisa ukuba i-breaker isebenza ngokuchanekileyo.
4. Uvavanyo lwe-SF6 yeGesi yeAnalyzer
Uvavanyo lwe-SF6 lwe-gas analyzer lwenziwa ukujonga ukucoceka kwegesi ye-SF6 ngaphakathi kwe-breaker circuit. Olu vavanyo lwenziwa ukuqinisekisa ukuba igesi ye-SF6 icocekile kwaye ayinabumdaka. Ukwenza olu vavanyo, i-SF6 ye-gas analyzer ixhunyiwe kwi-gas compartment ye-breaker circuit, kwaye ukucoceka kwegesi kulinganiswa.
Ukuvavanya i-SF6 i-breaker circuit breaker ibalulekile ekuqinisekiseni ukusebenza kwayo ngokufanelekileyo kunye nokhuseleko. Ukugcinwa rhoqo kunye nokuvavanywa kwe-circuit breaker kuya kuqinisekisa ukuba isebenza ngaphakathi kwenkcazo yomenzi kwaye ikhuselekile ukuyisebenzisa. Ukwenza iimvavanyo eziqhelekileyo usebenzisa ezi ndlela zingentla kuya kunceda ukufumanisa naziphi na iziphene okanye imiba kwi-breaker circuit kwaye uvumele ukulungiswa ngexesha elifanelekileyo okanye ukutshintshwa.