Umbuzo: Ndibona ibhokisi yentsimbi enkulu enezihlahla phezulu - isiguquli sovavanyo? Ndingayisebenzisa nini le endaweni yesitaki sereactor?
A: Ewe - isiguquli sovavanyo esiqhelekileyo linyathelo elilula-lokunyusa isiguquli (220/380V ngaphakathi, 10–300 kV ngaphandle). Esona sixhobo sincinci, siphantsi{7}}imithwalo enamandla njengee-CTs, ii-PTs, ii-bushings, kunye neentambo ezimfutshane (< 25 m).
Uyisebenzisa nini:
|
Uyavavanya... |
Ukubanakho |
Ukuvavanya TX? |
Ngoba? |
|
I-CT (i-transformer yangoku) |
50–200 pF |
✅ Eyona nto ingcono |
Umthwalo omncinci - i-TX iyiqhuba lula |
|
I-PT (inguqu enokwenzeka) |
100–500 pF |
✅ Eyona nto ingcono |
Isizathu esifanayo |
|
Amahlahla amancinci |
100–500 pF |
✅ Eyona nto ingcono |
Umthwalo olula wokuxhathisa |
|
Intambo emfutshane < 100 m |
< 20 nF |
✅ Umhle |
Ukutshaja okuphantsi ngokwaneleyo okwangoku |
|
Ibheyi yeGIS (isaphuli sesekethe) |
5–50 nF |
✅ Yamkelekile |
Phakathi C - KULUNGILE ngomda |
|
5 km intambo yamandla |
1 μF+ |
❌ Imbi |
Inkulu yangoku - bona i-FAQ 5 |
|
Istator yejeneretha |
1 μF+ |
❌ Akulunganga |
Ingxaki efanayo |
Ixabiso eliqikelelweyo (elitsha, ngo-2025):
50 kV / 5 kVA uvavanyo TX: $8,000–15,000
100 kV / 10 kVA uvavanyo TX: $20,000–40,000
200 kV / 50 kVA: $ 50,000+ - kodwa kunqabile; abantu batshintshela kwi-SR kweli nqanaba
Apho kusetyenziswe khona: Iilebhu zovavanyo lwefektri (CT/PT/bushing mfr), iifektri zokutshintsha izinto, iivenkile zokulungisa ezincinci.
Ingcebiso yoPro: "100 kV / 10 kVA" ukukala kuthetha ukuba inokubonelela nge-10 kVA kumthwalo ochasayo nge-100 kV. Kodwa kwintambo ye-capacitive, umsinga wokutshaja unokudlula i-10 kVA - nakwi-voltage echanekileyo. Leyo yindlela #1 abaqalayo abatshabalalisa ngayo abaguquli bovavanyo.